On Line UPS - HS
Series |
 |
|
Model |
2100HS |
2200HS |
2300HS |
|
Rated Power |
|
VA/W |
1KVA/0.7kW |
2KVA/1.4kW |
3KVA/2.1kW |
|
Input |
|
Nominal Voltage |
110VAC/220VAC |
|
Voltage Range |
60~138VAC/115~300VAC |
|
Frequency Range |
46~54Hz(default),user
adjustable within 40~60Hz |
|
Power Factor |
0.97 |
|
Output |
|
Voltage |
110VAC/220VAC±2% |
|
Frequency |
46-54Hz±0.2Hz(Line mode) 50Hz±0.2Hz(battery mode) |
|
Waveform |
sine wave |
|
Distortion |
3% |
4% |
|
Overload capability |
108%~150%for30secends.,±151%for300ms |
|
Current Crest Ratio |
3:1 |
|
Battery |
|
Type |
Sealed, Maintenance free, Lead-Acid |
|
Recharge Time |
5hrs to90%of capacity after full load discharge |
|
Bypass |
|
Automatic Transfer |
on overload and UPS failure |
|
Before UPS power-on |
Default "NO", user adjustable to "YES" |
|
Transfer time |
0ms;less than 4 ms from inverter to bypass and vice versa |
|
LED/LCD Indicators |
|
status |
load level/Battery level,
Battery, Utility power, Inverter, Bypass, Overload, Fault |
|
Audible Alarm |
Bypass, ON battery mode,
Battery low, Overload, Fault |
|
Acoustic Noise |
|
At 1 meter distance |
45 dBA |
50 dBA |
|
Communications |
|
DB-9Port |
RS-232 Serial Interface |
|
Intelligent Slot |
Options;Webpowet,As400 Card or WinPower CMC |
|
Environmental |
|
Operating Temperature |
0-40℃ |
|
Operating Humidity |
20~90%
non-condensing |
|
Weight |
|
Net (Kg) |
14/7 |
34/13.5 |
34.5/14 |
|
Dimensions |
|
W×D×H (mm) |
145*400*220 |
192*460*340 |
*
Specifications subject to change without prior notice |
|
|
|
►
On Line UPS - HS
Series (Rack) |
 |
w
Microprocessor Control Guarantees High Reliability
w
19 inch rack-mount
w
High frequency and dual conversion online technology
w
Advanced PFC technology
w
True sine wave output with less then 3%THD
w
Self-detection when UPS start-up
w
Advanced battery management
w
Cold start feature (DC power on)
w
Automatically charging batteries in UPS off made
w
Lighting and surge protections (surge energy rating
1050Joules)
w
Short circuit and overload protections
w
Fan speed automatically changes as load varies
w
Shutdown and restart schedule
|
|
Model |
2100HSR |
2200HSR |
2300HSR |
2600HSR |
|
VA/W |
1kVA / 0.7kW |
2kVA / 1.4kW |
3kVA / 2.1kW |
6kVA / 4.2kW |
|
Input |
|
Normal Voltage |
110Vac/220Vac |
|
Voltage Range |
60-138Vac/115-300Vac |
|
Frequency Range |
46-54Hz(Default),User adjustable within 40-60Hz |
|
Power Factor |
0.97 |
0.98 |
|
Connector |
IEC320 or NEMA Power cord |
Terminal Block |
|
Output |
|
Voltage |
110Vac/220Vac +/-2% |
|
Frequency |
50/60Hz +/-0.2Hz |
|
Waveform |
Sine Wave |
|
Power Factor |
0.7 |
|
Voltage Distortion |
0.2% under linear load |
|
Overload Capability |
108%-150% for 30Sec;150% for 300ms |
108%-130% for 10Min;
130% for 1Min |
|
Current Crest Ratio |
3:1 |
|
Bypass |
|
Automatic Transfer |
Overload and UPS failure |
|
Before UPS Power on |
Default "NO",User adjusable to :YES" |
YES |
|
Transfer time |
0ms |
|
LED/LCD indicator |
|
Status |
Load level/Battery level/Utility power/Inverter/Bypass/Fault |
|
Audible Alarm |
Bypass/Battery Mode/Battery Low/Overload/Fault |
|
Interface |
|
Communication |
RS232 serial interface |
|
Intelligent Slot |
Webpower SNMP/Web Card/AS400 |
|
Environmental |
|
Temperature |
0-40℃ |
|
Humidity |
20-90% Non-Condensing |
|
Weight |
|
Net (Kg) |
15.3 |
103 |
11.2 |
18.3 |
|
Dimensions |
|
W
x D x H (mm) |
48.2x450x88(2U) |
482*600*130(3U) |
|
Battery Pack |
|
Type |
Internal or External
Battery Pack |
External
Battery
Pack |
|
Normal Voltage |
36VDC |
96VDC |
240VDC |
*
Specifications subject to change without prior notice |
|
|
|
►
On Line UPS - 2B
Series |
 |
|
Model |
2B2KL(S) |
2B3KL(S) |
2B3.75 KL(S) |
2B5K/2B6KL(S) |
2B10K |
|
Output capacity |
2000VA |
3000VA |
3750VA |
5000/6000VA |
10000VA |
|
Input |
|
Voltage |
110VAC±20%/220VAC±25% |
|
Frequency |
60Hz±5%/50Hz±5% |
|
Ouput |
|
Voltage |
110V±1%/220V±1% |
|
Frequency |
60Hz±0.5%/50Hz±0.5%(Free running) |
|
Distortion |
THD<5%;THD<3%
Non linear load THD<5%;resistance load thd<3% |
|
Stability voltage at transient state |
Full load±4% |
|
wave form |
Sine wave |
|
Crest factor |
3:1 |
|
Power factor |
0.8-1 LAG |
|
AC/AC |
>85% |
|
Battery |
|
DC Voltage |
96V |
192V |
|
Number |
12V/7Ah×8pCS |
12V/7Ah×16pCS |
|
Transfer time |
|
AC fault |
0ms |
|
UPS fault |
<2ms |
|
Alarm |
|
AC fault |
alarm every 4 seconds,stop
after90 seconds |
|
battery low voltage |
alarm every 1 seconds until cut-off and battery LED flash every 2
seconds |
|
UPS over load |
Continue voice |
|
UPS fault |
Continue voice |
|
Protection |
|
Over load |
125%load ,change to by-pass and auto-restart after 25s |
|
Battery |
Circuit breaker |
|
Short circuit |
Breaker, current limited and cut-off |
|
Over temperature |
>85℃
change to by-pass |
|
EMI filter |
150~500K Hz ,79dB /500K~30M Hz ,73dB |
|
Display |
|
LED |
mains input/by pass/inverter/battery/over load/fault |
|
LCD |
Input &,output voltage or battery
voltage/frequency/load rate/UPS condition/temperature |
|
Interface |
|
RS232 |
mains/inverter voltage/battery capacity/load
capacity/mains frequency/temperature/ time-shutdown etc |
|
General data |
|
Temperature |
0℃~40℃ |
|
Humidity |
20~90% No condensing |
|
Noise |
<58dB at 1 meter |
|
Weight |
56/85kg |
64/93kg |
64/93kg |
77/126 kg |
106 kg |
|
Dimension
(W×D×H) mm |
585*230*720 |
585*230*580 |
585*230*720 |
585*230*580 |
480×340×845 |
|
Output socket |
1 connection bus |
*
Specifications subject to change without prior notice |
|
|
|
►
On Line UPS -
Series |
 |
Applications :
-
Data/Call Center
-
Telecommunications
-
Medical
-
Security
-
Semiconductor
-
Chemical
|
|
Power rating (PF=0.8) |
15KVA
(12KW) |
20KVA
(16KW) |
30KVA
(24KW) |
40KVA
(32KW) |
50KVA
(40KW) |
60KVA
(48KW) |
80KVA
(64KW) |
|
Input |
|
Rating Voltage |
220/380V, 230/400V, 240/415V (3phase, 4-wire plus ground) |
|
Voltage Regulation |
-25%~+20% |
|
Input Current Harmonic Distortion (Full Load) |
<3 |
|
PF |
>0.99 Hz |
|
Frequency |
50/60 Hz |
|
Frequency Tolerance |
45~65 Hz |
|
Output |
|
Output Voltage |
220/380V, 230/400V, 240/415V (3phase, 4-wire plus ground) |
|
Output Frequency |
50/60Hz |
|
Voltage Harmonic |
≤3% (Linear Load) |
|
Voltage Regulation |
Static |
≦1% |
|
Dynamic |
≦7% (10%~90% Linear Load) |
|
Frequency Regulation |
Interior Oscillator |
±0.05Hz |
|
Synchronized |
±0.5Hz |
|
Overload |
≦125%:10 minutes; ≦150%: 1 minute |
|
Audible Warming |
|
Battery Backup |
Intermittent |
|
UPS Abnormal |
Continuous |
|
Display |
|
LED |
UPS Status: Normal、Bypass、Backup、Fault
|
|
LCD |
Input/Output、Bypass、Inverter、Frequency、Loading
and Battery Voltage、Current
UPS Abnormal Message and Intelligent Self Diagnosis |
|
Interface |
|
Standard |
RS232x1, Smart Slotx2, Dry Contact Outputx6,Contact Inputx2,
Parallel Portx1, Battery Cabinet Temperaturex4 |
|
Optional Accessories |
SNMP Card Modbus Card, Relay I/O Control Card, Environmental
Sensor Box,
SNMP+5 Port Hub, Battery Cabinet Temperature Sensor.
Battery Cabinet Temperature Kit (For Delta Battery Cabinet),
Battery Cabinet Status Cable. |
|
Others |
|
Parallel Redundancy |
Yes (1+1Redundancy, Maximum 160KVA) |
|
EPO |
Standard (Local and Remote) |
|
SRAM |
Yes (500 Records) |
|
Parameter Configuration |
Yes |
|
Hot Standby Installation |
Feasible |
|
Battery Temperature |
Optional |
|
Battery Start |
Standard |
|
Complete system |
|
Efficiency |
Normal |
94% |
|
ECO |
97% |
|
Transfer Time |
0 Ms |
|
Temperature |
0~40℃ |
|
Humidity |
90% (Non Condensed) |
|
Noise (One Meter) |
65DBA |
65DBA |
68DBA |
68DBA |
70DBA |
70DBA |
70DBA |
|
Dimension |
Width |
520 mm |
|
Depth |
850 mm |
|
Height |
1165 mm |
|
Weight |
125kg |
125kg |
175kg |
175kg |
210kg |
210kg |
244kg |
*
Specifications subject to change without prior notice |
|
|